Any user that will be accessing the IoTServer using SNMPv3 will require additional settings for authentication an privacy. Those are provided here. The definition of "user" can include other machines that wish to query the MIB in the IoTServer.
+
Any user that will be accessing the IoTServer using SNMPv3 will require additional settings for authentication and privacy. Those are provided here. The definition of "user" can include other machines that wish to query the MIB in the IoTServer. IMPORTANT: Use a passphrase of at least 10 characters. A very short phrase will be rejected by the encryption algorithm and be indicated as an encryption error.
 
+
<hr>
 
[[File:User settings edit 4.jpg]]
 
[[File:User settings edit 4.jpg]]
  
If your system uses SNMPv3, users will have to be defined to interact with other SNMP devices. You will be able to choose access permissions for SNMP Agent users, as well as SNMP Trap Receiver users. The SNMP user settings will be used in generating the SNMP configuration files.
+
Any device that will be sending SNMPv3 traps to this IoTServer will require its own user credentials. In addition to the authentication and privacy settings required for any SNMPv3 user, the trap receiver user must also include the Engine ID of the device that will be sending traps to this IoTServer. If all credentials including Engine ID do not match, then the received trap will be discarded.  
 
 
If the user has access to the SNMP Trap Receiver, you must also specify a unique engine ID for this user. SNMP devices will use this id in identifying your system when sending traps.
 
  
 
== Other Notes ==
 
== Other Notes ==
  
 
Note: Users logging in via RADIUS will not have the opportunity to edit their profiles. In this case, they are defaulted to web only users with a default Modbus number display format. Passwords and usernames are controlled by the registered RADIUS server.
 
Note: Users logging in via RADIUS will not have the opportunity to edit their profiles. In this case, they are defaulted to web only users with a default Modbus number display format. Passwords and usernames are controlled by the registered RADIUS server.

Latest revision as of 13:16, 19 May 2021

User Settings

User settings edit 1.jpg

Local users can be edited by choosing their name from the list found in System->Users, or they can edit themselves by clicking on "User Settings" in the top right corner of any web page.

User settings edit 2.jpg

A password and username can be set on this page. Users will be assigned access permissions, or "roles," as well. A user that logs into the local web interface would be required to have "Web" permissions.

Modbus User Settings

User settings edit 2a.jpg

Every local user has the option of setting the display settings for Modbus registers. The user can select:

  • Address
  • Number
  • Modicon

Once a local user selects a format, all Modbus registers will be formatted as such throughout the web UI.

SNMP Settings

User settings edit 3.jpg

Any user that will be accessing the IoTServer using SNMPv3 will require additional settings for authentication and privacy. Those are provided here. The definition of "user" can include other machines that wish to query the MIB in the IoTServer. IMPORTANT: Use a passphrase of at least 10 characters. A very short phrase will be rejected by the encryption algorithm and be indicated as an encryption error.


User settings edit 4.jpg

Any device that will be sending SNMPv3 traps to this IoTServer will require its own user credentials. In addition to the authentication and privacy settings required for any SNMPv3 user, the trap receiver user must also include the Engine ID of the device that will be sending traps to this IoTServer. If all credentials including Engine ID do not match, then the received trap will be discarded.

Other Notes

Note: Users logging in via RADIUS will not have the opportunity to edit their profiles. In this case, they are defaulted to web only users with a default Modbus number display format. Passwords and usernames are controlled by the registered RADIUS server.